Mitsubishi Electric PLK-J Series Technical Manual page 56

Industrial sewing machine operation panel
Table of Contents

Advertisement

■List of code data
Code
2HP
2nd home position
USTP
Needle UP halt
DSTP
Needle DOWN halt
TRIM
Thread trimming
BAT
Basting
EXT1 : Extension code
ASRT : Automatic start after stopping
EXT3 : Extension code
F1_H to FH_H : FN (1 to H) Output ON
F1_L to FH_L : FN (1 to H) Output OFF
EXT2:Extension code
DFTH:Detecting material thickness
setting
Making method of using BAT (Basting or more than 20mm stitch length) code.
The sewing data which exceeds the stitch length limitation of 20mm can be made by using this BAT
code.
[Example] The following type of sewing data will be created.
(1) Input the "BAT" codes after input the feed data to A point
►Press
.
Function
[7]‐21
Code
Function
FUN1
Function code 1
FUN2
Function code 2
FUN3
Function code 3
FUN4
Function code 4
FUN5
Function code 5
FUN6
Function code 6
FUN7
Function code 7
FUN8
Function code 8
FUN9
Function code 9
FUNA
Function code A
FUNB
Function code B
FUNC
Function code C
FUND
Function code D
FUNE
Function code E
FUNF
Function code F
FUNG
Function code G
FUNH
Function code H