Operation

AUTOMATIC SYSTEM ACTIVATION HAZARD
Unexpected activation of the system could result in
serious injury, including skin injection and amputa-
tion.
This device has an automatic timer that activates the
pump injection system when power is connected or
when exiting the programming function. Before you
install, service, or remove the pump from the system,
pull the motor fuse (see pump manual) and discon-
nect and isolate all power supplies.

Cool Down Mode

When the controller detects that it is too hot, it will turn
the pump off and display "HOT". Once it has cooled
down, the controller will automatically resume running.

Setup Modes

See Calculating On and Off Times for Batch Treat-
ment, page 8, for information on how to calculate the
On and Off Time values entered in Setup Mode.

Set Up On Time

1. While in Run Mode (either of the ON or OFF LEDs
are lit and not blinking), press the ON TIME button
(E) to enter On Time Setup Mode (the ON LED is
blinking). (See Keypad, Display, and Icons on
page 4.)
The first press of the ON TIME button (E) activates
the DAY LED dot in the Display (F) and displays
days.
2. Press and hold the Up or Down arrow buttons (D) to
increase or decrease the duration of On Time in
days. (The rate of increase or decrease increases
the longer an arrow button is held.)
3. Press the ON TIME button (E) again to activate the
HOUR LED dot in the Display (F) and to display
hours.
3A8606A
4. Press and hold the Up or Down arrow buttons (D) to
increase or decrease the duration of On Time in
hours.
5. Press the ON TIME button (E) again to activate the
MIN LED dot in the Display (F) and to display min-
utes.
6. Press and hold the Up or Down arrow buttons (D) to
increase or decrease the duration of On Time in
minutes.
7. Press the ON TIME button (E) again to activate the
SEC LED dot in the Display (F) and to display sec-
onds.
8. Press and hold the Up or Down arrow buttons (D) to
increase or decrease the duration of On Time in
seconds.
9. Press the ON TIME button (E) again to save the On
Time values. "SAvE" appears in the Display (F) and
the controller returns to Run Mode.

Set Up Off Time

1. While in Run Mode (either of the ON or OFF LEDs
are lit and not blinking), press the OFF TIME button
(C) to enter Off Time Setup Mode (the OFF LED is
blinking). (See Keypad, Display, and Icons on
page 4.)
The first press of the OFF TIME button (C) activates
the DAY LED dot in the Display (F) and displays
days.
2. Repeat steps 2-9 in Set Up On Time while substi-
tuting Off Time and the OFF TIME button (C) for On
Time and the ON TIME button (E).