3.22 Implement setup

3.22.1 Change the implement settings

Procedure
1.
Select the icons in this order:
2.
If a lift switch is connected, enable the lift
switch (1).
3.
If the lift switch is reversed, make sure there
is a checkmark in the box (2) next to
Reversed.
4.
Select the box (3) next to Low Speed Alarm
to set the low fan speed alarm.
5.
To hear a sound each time the master apply
switch is turned on, enable the master apply
beep (4).
6.
Select the ground speed source (5).
° Drill GPS
° ISOBUS
7.
Select the type of rate control (6).
° Per section
° Full width of the implement
8.
The section measurements (7) are determined by the openers on the machine.
9.
With the req fan A (8) selected the minimum fan speed must be met or the machine will not apply.
10.
Select
to go back to the main screen.

3.22.2 Calibrate a drill section

NOTE: The catch bag must be empty each time the calibration process is started.
Procedure
1.
Weigh the empty container.
2.
Put the container in position to catch the product from one section.
3.
On the terminal, select the icons in this order:
Narrow-Transport Grain
Drill (322782B)
Fig. 62
97
3. Operation
[V]
GUID-5DC9136F-C449-49EA-9C52-C9FC3F1374BB [V3]
GUID-313605D0-DE48-48BE-8FEC-AE262F3E16A3-low.png [Low]
GUID-CD06ACCE-2244-4068-AAC8-C5E8AA3347E2 [V2]