If two tags enter the read range one immediately after the other, the status '05h' is
not issued between the two readings.
7.2.7

Special command modes

Commands for the data carrier IPC03
Note!
You can only use the commands in this section for the data carrier type '03'
(IPC03).

IPC03 Configuration

The storage of a data carrier IPC03 is organized by word. A data word is defined
with a length of 32 bits. For the normal data range, 29 words from addresses 3
through 31 (<WordAddr> = 00h ... 1Ch) are available.
Address
Word 0
Word 1
Word 2
Word 3 ...31
Word 32
Word 33
Word 0 contains the password. The password can only be written.
With word 1, the "Protection Word", you can define a read-protected and a write-
protected range. The "Protection Word" can only be read and written with the
correct password.
With word 2, the "Control Word", you can set various operating modes and the
read range for the operating mode "Default Read". The "Control Word" can only
be read and written with the correct password.
If you would like to use the "Protection Word" and the "Control Word", you must
first activate the password mode.
The individual bits have the following meanings:
Protection word
Bit
0 ... 7
8 ... 15
16 ... 23
24 ... 31
Meaning
<WordAddr> <ConfAddr>
Password
Protection word
Control word
Data range
00h ... 1Ch
Device Serial Number
Device identification
Meaning
First read-protected word
Last read-protected word
First write-protected word
Last write-protected word
-
-
-
1
-
2
-
1Dh
-
1Eh
-
Byte
Note
Write only
Read/write
Read/write
Read/write
Read only
Read only
0
1
2
3
45