IC-KP2-2HB21-2V1D
Product Description
4.7

Displays and Controls

Figure 4.7
LEDs
Description
1
2
CH1
CH2
PWR
RUN
Link/Act
LED RUN
Off
Flashes
green
Flashes
green once
Lights up
green
1
CH1
CH1
RUN
PWR
Link/
Link/
Act
Act
IN
Function
Status display for
read/write heads
Indicates that a
read/write head is
connected
Status display for
IDENTControl Compact
See table below
Connection/network
activity for the relevant
channel (1/2)
Status
INITIALIZATION
PREOPERATIONAL
SAFE OPERATIONAL
OPERATIONAL
2
CH2
CH2
OUT
Status description
LED lights up green when there is an active
command on the read/write head.
LED illuminates yellow for approx. 1 second
when a command has been successfully
executed.
LED lights up green when a read/write head
is connected to channel 1 or channel 2.
LED lights up red when a configuration error
occurs.
LED lights up green when the IDENTControl
Compact is connected to a power supply
and the interface is ready for operation.
LED lights up red if a hardware fault occurs.
LED is off until initial communication is made
via the Ethernet.
LED lights up green when a connection to
the network is established.
LED flashes yellow in the rhythm at which
data is sent.
Status description
The device is in the initialization phase.
Communication on the service channel.
No process data exchange.
Synchronization is taking place.
Valid inputs are transferred.
Outputs remain in a secure state.
Normal communication. Synchronous data
exchange with the master.
15