Communication via the RS 232 interface

The serial RS 232 interface enables the quick and easy connection of the
IDENTControl Compact to a PC or PLC.
You can use the diagnostic function to retrieve information via the IDENTControl
Compact and the connected R/W heads. The information includes details such as
the device version, software date, type and version of the connected R/W head,
preset handheld parameters, and the tag type.
Any kind of terminal program can be used to control communication. We
recommend RFIDControl software, which is available from Pepperl+Fuchs free of
charge.
The following RS 232 interface parameters are fixed:
Baud rate 38 400, 8 data bits, 1 stop bit, no parity.
7.3.1
Command examples
Note!
Enter all commandswithout spaces!
1. Example: Set tag type
Tag type "99" is preset on delivery. The tag type is used which is stored on the
R/W head.
Send the command Change tag described in the Command table to select the
tag type IPC03 for the R/W head connected to channel 1.
You should receive one of the responses described in the Response table.
Command:
CT 1 03 # <CR>
CT
1
03
#
<CR>
78
Meaning
10h
Reserved
20h
Reserved
40h
Incorrect or incomplete command or parameter not in the valid
range.
TCP/IP: The specified length of the message does not match the
actual length.
Change tag command
Channel 1
Tag type IPC03
End character
End character