TO THE INSTALLER
injury from electrical shock.
IMPORTANT! An equipotential grounding lug is
provided with this machine. Some countries require the
grounding lug to be properly attached to the rear of the
1
frame by the authorized installer. The installation location
is marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on both the removable panel and the
machine's frame.
IMPORTANT!
Stationary machines which are not equipped
with a power cord and a plug or another device
to disconnect the machine from the power
source must have an all-pole disconnecting
device with a contact gap of at least 0.125 in.
(3 mm) in the external installation.
Machines that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by authorized personnel to local
codes.
Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
If the supply cord is damaged, it must be replaced by a
Taylor service technician to avoid a hazard.
1-2

Installation

alteration, service, or maintenance can cause property
damage, injury, or death. Read the installation, operating,
and maintenance instructions thoroughly before installing
or servicing this machine.
Important! This machine is designed for indoor use only.
area where a water jet could be used. Failure to follow
this instruction may result in serious electrical shock.
level surface. Failure to comply may result in personal
injury or machine damage.

Installation of Cable Kit

If the machine is permanently connected, the cable kit
must be installed. Flexible conduit must be used when
installing the machine.

Ventilation and Clearance

To ensure proper operation of this machine, it must be
installed so products of combustion are efficiently
removed.
on top of the grill. Failure to follow this instruction may
result in a fire hazard.

Grease Disposal Container

If the grill is not factory-equipped with grease disposal
containers, the store is required to provide appropriate
grease disposal containers in accordance with NSF
Standard 4 requirements.