Komatsu PC400LC-5 Operation & Maintenance Manual page 91

Hydraulic excavator
Table of Contents

Advertisement

12.3
OPERATIONS
AND CHECKS AFTER
STARTING
ENGINE
l
Emergency
stop
If there has been any abnormal
actuation
or trouble,
turn the
starting
switch
key to the OFF position.
l
If the
work
equipment
is operated
without
warming
the
machine
up sufficiently,
the response
of the work equipment
to the movement
of the control
lever will be slow,
and the
work
equipment
may not move as the operator
desires,
so
always
carry out the warming-up
operation.
Particularly
in
cold areas,
be sure to carry out the warming-up
operation
fully.
12.3.1 WHEN NORMAL
NOTICE
l
When the hydraulic
oil is at a low temperature,
do not carry out
operations
or move the levers suddenly.
Always
carry out the
warming-up
operation.
This will help to extend the machine
life.
l
Do not suddenly
accelerate
the engine
before the warming-up
operation
is completed.
Do not run the engine at low idling or high idling continuously
for more than 20 minutes.
This will cause leakage of oil from the
turbocharger
oil supply
piping.
If it is necessary
to run the
engine at idling, apply a load from time to time or run the engine
at a mid-range
speed.
After starting
the engine,
do not immediately
start operations.
First, carry out the following
operations
and checks.
1.
Turn fuel control
dial @ to the center
position
between
LOW
IDLING
(MINI
and HIGH IDLING
(MAX)
and run the engine
at
medium
speed for about 5 minutes
with no load.
2.
While running the engine at medium
speed, press working
mode
switch @ until the heavy-duty
operation
mode lamp is turned on.