16. TROUBLESHOOTING
Connecting
the booster
cables
Keep the starting
switch at the OFF position.
Connect the booster
cable as follows,
in the order of the num-
bers marked
in the diagram.
1.
2.
3.
4.
5.
Make sure that the starting switches
of the normal
machine
and
problem
machine
are both at the OFF position.
Connect
one clip of booster cable @ to the positive @ terminal
Engine block of the problem machine
of the problem
machine.
AD052e80
Connect
the other
clip of booster
cable @ to the positive
@
terminal
of the normal
machine.
Connect one clip of booster cable @ to the negative
@terminal
of the normal
machine.
Connect the other clip of booster cable @to
the engine block of
the problem
machine.
Starting
the engine
1.
Make sure the clips are firmly connected
to the battery terminals.
2.
Start the engine of the normal machine
and keep it to run at high
idling speed.
3.
Turn the starting
switch of the problem
machine
to the START
position and start the engine.
If the engine doesn't start at first,
try again after 2 minutes
or so.