12. OPERATION
5.
If the oil is above the H mark, drain the excess engine
oil from
[
III
drain plug 8,
and check
6.
If the oil level is correct,
close the engine
hood.
the oil level again.
I
III
tighten
the oil filler cap securely
and
When checking the oil level after the engine
has been operated,
wait for at least 15 minutes
after stopping
the engine
before check-
ing.
REMARK
0
I
AE0974.90
If the machine
is at an angle,
make it horizontal
before checking.
CHECK FUEL LEVEL, ADD FUEL
g
WARNING
When
adding fuel, never let the fuel overflow.
This may cause
a fire. If you spill fuel, thoroughly
clean up any spillage.
1.
Use sight gauge @ on the front face of the fuel tank to check that
the tank is full.
2.
if the fuel level is not within
the sight gauge,
add fuel through
filler port @ while watching
sight gauge
0.
Fuel capacity:
550 f? (145 US gal, 121 UK gal)
For details of the fuel to use, see "20. USE OF FUEL, COOLANT
AND LUBRICANTS
ACCORDING
TO AMBIENT
TEMPERATURE".
3.
After adding
fuel, tighten
the cap securely.
REMARK
If breather
hole @ on the cap is clogged, the pressure in the tank
will drop and fuel will not flow.
Clean the
hole from time to time.
AE097500
2-38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc400Pc400-5 mightyPc400hd-5