16. TROUBLESHOOTING
16.6.3 ENGINE
0
(
1:
Always
contact
your
Komatsu
distributor
when
dealing
with these items.
l
In cases of abnormalities
or causes
which
are not listed
below,
please
contact
your
Komatsu
distributor
for repairs.
Problem
Engine
oil pressure
monitor
lights
up
Steam
is emitted
from
top
part
of radiator
(pressure
valve)
Radiator
water
level
monitor
lights
up
Engine
does
not start when
starting
motor
is turned
Main causes
Engine
oil pan oil level
is low
(sucking
in air)
Clogged
oil filter
cartridge
Defective
tightening
of oil pipe
joint,
oil leakage
from
damaged
part
Defective
engine
oil pressure
sensor
Cooling
water
level
low, water
leakage
Loosen
fan belt
Dirt or scale accumulated
in
cooling
system
Clogged
radiator
fin or
damaged
fin
Defective
thermostat
Loose
radiator
filler
cap (high
altitude
operation)
Defective
water
level sensor
Lack of fuel
Air in fuel
system
Defective
fuel
injection
pump
or
nozzle
Starting
motor
cranks
engine
sluggishly
Preheating
monitor
does
not
light
up
Defective
compression
o
Defective
valve
clearance
Remedy
l
Add
oil to specified
level,
see
CHECK
BEFORE
STARTING
l
Replace
cartridge,
see EVERY
250 HOURS
SERVICE
(o Check,
repair)
(o Replace
sensor)
Add
cooling
water,
repair,
see
CHECK
BEFORE
STARTING
Adjust
fan belt tension,
see
EVERY 250 HOURS
SERVICE
Change
cooling
water,
clean
inside
of cooling
system,
see
WHEN
REQUIRED
Clean
or repair,
see EVERY
500 HOURS
SERVICE
Replace
thermostat)
Tighten
cap or replace
packing
Replace
sensor)
l
Add
fuel,
see CHECK
BEFORE
STARTING
l
Repair
place where
air is
sucked
in, see EVERY 500
HOURS
SERVICE
(e Replace
pump
or nozzle)
1
J
See ELECTRICAL
SYSTEM
(o
Adjust
valve
clearance)
2-96

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: