CHECK OIL LEVEL IN HYDRAULIC
TANK,
ADD OIL
a
WARNING
1
l
When
removing
the oil filler cap, oil may spurt out, so turn
the cap slowly to release the internal
pressure
before remov-
ing the cap.
l
If oil has been added to above the H mark, stop the engine
and wait
for the hydraulic
oil to cool down,
then drain the
excess oil from the drain plug.
I
I
If the work
equipment
is not in the condition
shown
in the
diagram
on the right, start the engine,
run the engine
at low
1.
2.
3.
speed,
retract
the arm
and
bucket
cylinders,
then
lower
the
boom, set the bucket teeth in contact with the ground,
and stop
the engine.
Within
15 seconds after stopping
the engine,
move each control
lever (for work
equipment
and-travel)
to the full stroke
in all
1
Iul
/
directions
to release the internal
pressure.
Check sight gauge 0. The oil level is normal if between
the H and
L marks.
AE082200
NOTICE
Do not add oil if the level is above the H line. This will damage
the hydraulic
equipment
and cause the oil to spurt out.
4.
If the level is below the L mark, remove
the upper cover of the
hydraulic
tank and add oil through
oil filler 0.
H
For details of the oil to use, see "20. USE OF FUEL, COOLANT
AND
LUBRICANTS
ACCORDING
TO AMBIENT
TEMPERATURE".
REMARK
The oil level will vary depending
upon the oil temperature.
Accordingly,
use the following
as a guide:
l
Before operation:
around
L level
(Oil temperature
10 to 30°C (50 to 86°F))
l
Normal
operation:
around
H level
(Oil temperature
50 to 80°C (122 to 176°F))
AE082220