Komatsu PC400LC-5 Operation & Maintenance Manual page 188

Hydraulic excavator
Table of Contents

Advertisement

5.
If the oil is above the H mark, drain the excess engine
oil from
drain valve @, and check the oil level again.
I
6.
If the oil level is correct, tighten
the oil filler cap securely
and
0
close the engine
hood.
REMARK
When checking the oil level after the engine
has been operated,
wait for at least 15 minutes after stopping the engine before checking.
If the machine
is at an angle,
make it horizontal
before checking.
I
AEO97480
24.3.3 CHECK FUEL LEVEL, ADD FUEL
A
WARNING
When
adding fuel, never let the fuel overflow.
This may cause
a fire. If you spill fuel, thoroughly
clean up any spillage.
1.
2.
Use sight gauge on the front face of the fuel tank to check that
the tank is full.
If the fuel level is not within
the sight gauge,
add fuel through
filler port 0,
while watching
sight gauge.
Fuel capacity:
550 e (145 US gal, 121 UK gal)
For details of the fuel to use, see "20. USE OF FUEL, COOLANT
AND
LUBRICANTS
ACCORDING
TO AMBIENT
TEMPERATURE".
3.
After adding
fuel, tighten
the cap securely.
REMARK
If breather
hole @ on the cap is clogged, the pressure in the tank
will drop and fuel will not flow.
Clean the hole from time to time.
AE097500