11. EXPLANATION OF COMPONENTS
11 .I.4
D: METER DISPLAY PORTION
PILOT DISPLAY
When the starting switch is ON, the pilot display lights up when
the display
items are functioning.
METERS
1.
ENGINE WATER TEMPERATURE GAUGE
This gauge
indicates
the engine
cooling
water temperature.
If the temperature
is normal
during operation,
the green range will
light up.
If the red range lights up during operation,
the overheat
prevention
system will be actuated.
If the red range flashes, engine water temperature
monitor @ flashes
and alarm
buzzer sounds
at same
time,
the overheat
prevention
system will be actuated.
The overheat
prevention
system
acts as follows.
When
red range @ lights up:
The power
mode switched
to L mode for each working
mode,
and engine
water temperature
monitor
@ flashes.
When
red range @ lights up:
Engine
speed
is lowered
further
to low
idling,
engine
water
temperature
monitor
@ flashes and alarm buzzer sounds at the
same time.
1
2
nlldl?
wiVt&~&>
Fied
Green
AD096980
1
2-9