30.
HANDLING AIRCONDITIONER
Check volume
of refrigerant
has)
,
I
If there is a lack
of
refrigerant,
the cooling
performance
will be
poor.
When
operating
the cooler
at high speed, there
should
be no
bubbles
in the sight
glass
(inspection
window)
mounted
on the
condenser
unit receiver.
If there are any bubbles,
there is a lack of gas, so have to add
refrigerant
at a shop.
0:
Sight glass
@: No refrigerant
0:
Lack of refrigerant
0,: Correct amount
of refrigerant
AE099150
The refrigerant
used in the cooler is colorless and odorless,
and
However
if it
gets in the eyes or on the hands, it will be cause of frostbite
or
loss of sight, so never loosen any part of the refrigerant
circuit.
Check during
off-season
When the air conditioner
is not being used, run the compressor
at low speed for a few minutes
every week to avoid loss of oil. (Run
the engine at low speed with the cooler temperature
regulator
knob
at LOW COOL.)
In cold weather,
do not run the compressor
suddenly
at high
speed.
This
may
cause
failure
in the
compressor.
When
the
temperature
is below
2 to 6.5"C, the low pressure
cut-off
switch
functions
to stop the compressor
from running
even when
the air
conditioner
switch
is pressed.
5-11