24. SERVICE
PROCEDURE
l
4.
5.
6.
7.
8.
9.
Prepare
a container
to catch drained
coolant:
Min 34 P (9.0 US
gal, 7.5 UK gal) capacity.
If a corrosion
resistor cartridge
is installed,
close valves 0.
Turn radiator
cap @ slowly to remove
it.
Remove the undercover,
then set a container to catch the coolant
under drain valve @ and drain plug 0.
Open drain valve @ at
the bottom of the radiator to drain the water. Remove drain plug
@ in the cylinder
block when
draining
the water.
After draining
the water,
close drain valve @ and drain plug 0,
and fill with city water.
Open drain valve @ and drain plug 0,
run the engine
at low
idling, and flush water through
the system for IO minutes.
When
doing this, adjust the speed
of filling
and draining
the
water
so that the radiator
is always
full.
While
flushing
water
through
the system,
watch
carefully
that
the water
inlet hose does not come out of
the radiator
water
filler.
After flushing,
stop the engine,
open drain valve @ and drain
plug 0,
then close it again after all the water
has drained
out.
A&
AE0984-80
After draining
the water,
clean with a flushing
agent.
We recommend
use of a Komatsu
genuine
cleaning
agent.
For
details of the cleaning
method,
see the instructions
given with
the cleaning
agent.
After cleaning,
open drain valve @ and drain plug @to
drain all
the cooling
water,
then close them
and fill slowly
with clean
water.
When
the water
comes
up to near the water
filler
port, open
drain valve @ and drain plug 0,
run the engine at low idling, and
continue
to run water through
the system
until clean colorless
water
comes
out.
When
doing this, adjust the speed of filling and draining
the water
so that the radiator
is always
full.