24. SERVICE
PROCEDURE
24.2.9
CLEAN LINE FILTER
If there
is any abnormality
in the
pump
or other
hydraulic
equipment,
remove
the dirt from inside the line filter as follows.
Before
removing
the line filter, release the pressure
inside the
hydraulic
circuit.
For details,
see "18.4
PRECAUTIONS
WHEN
DISASSEMBLING
MACHINE".
Remove
case 0,
then remove
element
@ and clean it.
Some
of the oil inside the piping
will come out, so prepare
a
container
to catch it.
Remove
the dirt stuck inside the case.
Install element
0,
then screw in case 0
to install it.
Replace O-ring @and
backup ring @as a set when reassembling.
Tinhteninn
toraue
Case 0:
440 f 5 Nm (4.5 f 0.5 kgm, 32.5 f 3.6 Ibft)
After reassembling
the line filter, bleed the air from the circuit.
For details,
see "18.5 BLEEDING
AIR FROM CIRCUIT".
AE098580
AE098590
24.2.10
DRAIN WATER FROM WATER SEPARATOR
When float @ is at or above red line 0, drain the water according
to the following
procedure:
1.
Loosen drain plug @ and drain the accumulated
water
until the
float reaches the bottom.
2.
Tighten
drain plug 0.
3.
If the air is sucked into the fuel line when draining
the water,
be
sure to bleed the air in the same
manner
as for the fuel filter.
(For details,
see "24.6.1
REPLACE FUEL FILTER CARTRIDGE".)
3-42