12. OPERATION
CHECK DUST INDICATOR
When the air cleaner
element
is clogged,
the red piston
of dust
indicator
@ reaches
the service
level and gets locked.
After cleaning
the element,
push the button
to return the red
piston.
For details
of method
of cleaning
the
element,
see
"24.2.1
CHECK, CLEAN AND
REPLACE AIR CLEANER
ELEMENT".
AE097530
CHECK ELECTRIC WIRINGS
/*
WARNlNGI
If fuses are frequently
blown or If there are traces of short cucurt
on the electrical
wiring,
locate the cause and carry out repair.
Check for damage
of the fuse and any sign of disconnection
or
short circuit in the electric wiring.
Check also for loose terminals
and
tighten
any loose parts. Check the following
points carefully.
l
Battery
0
Starting
motor
l
Alternator
Please contact
your Komatsu
distributor
for investigation
and
correction
of the cause.
etc.) around
the battery
may cause fire, so always
check and
When carrying out walk-around
checks or checks before starting,
always
check if there
is any accumulation
of flammable
material
around
the battery,
and remove
such flammable
material.
LUBRICATE
CLAMSHELL
BUCKET
0
Prepare
a grease
pump.
1.
Place the work equipment
in a stable
posture
on the ground,
then stop the engine.
2.
Using
a grease
pump,
pump
in grease
through
the
grease
fittings
shown
by arrows.
3.
After greasing,
wipe off any old grease that was pushed
out.
AE097540