Commissioning

2.13 Commissioning SIMOTICS 1FW6 built-in torque motors

2.13
Commissioning SIMOTICS 1FW6 built-in torque motors
2.13.1

Safety instructions for commissioning

There is danger of death, serious bodily injury and/or property damage when untrained
personnel is allowed to handle direct drives and/or their components.
Only personnel who are familiar with and who observe the safety guidelines are allowed to
handle direct drives and their components.
Installation, commissioning, operation and maintenance may only be performed by
qualified, trained and instructed personnel. The personnel must be thoroughly familiar with
the content of this guide.
All work must be performed by at least two persons.
Risk of death, serious personal injury, and/or material damage if a machine is
commissioned that does not fulfill the recognized safety requirements.
Plants and machines with converter-fed low-voltage three-phase motors must fulfill the
protection requirements of the EMC Directive 2004/108/EC. The company building the plant
or system is responsible for ensuring that installation is carried out in an EMC-compliant
manner. The signal and power cables must be shielded. Refer to the EMC installation
guideline (order designation 6FC5297-□AD30-0AP□) issued by the converter manufacturer.
Unexpected movements of the motor may result in a risk of death, serious personal, and/or
material damage.
Danger from rotating rotor. Never carry out work in the vicinity of rotating parts when the
machine is switched on.
Keep persons away from rotating parts and areas where there is a danger of crushing.
Ensure that the rotors can rotate without hindrance.
Check the commutation setting before switching on the machine. Note also the
commissioning instructions issued for the drive system.
Limit the motor currents.
Set low values for speed limiting.
Monitor limit positions.
166
DANGER
DANGER
DANGER
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
Commissioning Manual

Advertisement

Table of Contents
loading

Table of Contents