Diagnostics
3.1 Diagnostics via LEDs
3.1.3.4

Sensor Module Cabinet SMC40

Table 3- 36
Meaning of the LEDs on the Sensor Module Cabinet-Mounted SMC40
LED
Color
RDY
READY
Green
Orange
Red
Green/red Flashing light
Green/
orange
or
Red/
orange
Each channel has a multifunction LED.
3.1.3.5

Communication Board CBC10 for CANopen

Table 3- 37
Meaning of the LEDs on the Communication Board CAN CBC10
LED
Color
OPT
on the
Control
Unit
Green
Red
264
Status
Description, cause
Off
Electronics power supply is missing or outside the
permissible tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
light
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
At least one fault is present in this component.
light
Note:
LED is controlled irrespective of the corresponding
messages being reconfigured.
Firmware download is complete. Waiting for POWER ON.
2 Hz
Flashing light
Component recognition via LED is activated (p0144).
Note:
Both options depend on the LED status when module
recognition is activated via p0144 = 1.
State
Description, cause
Off
Electronic power supply is missing or outside permissible
tolerance range.
Communication Board either defective or not inserted.
LED ON
OPERATIONAL
LED
PREOPERATIONAL
Blinking
No PDO communication possible
LED
STOPPED
Single
Only NMT communication possible
flash
LED ON
BUS OFF
LED
ERROR PASSIVE MODE
Single
The error counter for "error passive" has reached the value
flash
127. After the SINAMICS drive system was booted no
further active CAN component was on the bus.
LED
Error Control Event, a Guard Event has occurred
Double
flash
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON
Remedy
Check baud rate
Check cabling
Check baud rate
Check cabling
Check connection to
CANopen master
Commissioning Manual