Siemens SINAMICS S120 Commissioning Manual page 156

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning
2.12 Notes on commissioning linear motors
154
The following motor data must be entered for third-party motors:
Parameter
p0305
p0311
p0315
p0316
p0322
p0323
p0338
p0341
p0350
p0356
Optionally, further motor data (linear synchronous motor) can be entered for third-party
motors:
Parameter
p0312
p0317
p0318
p0319
p0320
p0325
p0326
p0329
p0348
p0352
p0353
p0391
p0392
p0393
Description
Rated motor current
Motor rated velocity
Motor pole pair width
Motor force constant
Maximum motor velocity
Maximum motor current
Motor limit current
Motor weight
Motor stator resistance, cold
Motor stator leakage inductance
Description
Rated motor force
Motor voltage constant
Motor stall current
Motor stall force
Rated motor magnetizing current
Motor pole position identification current 1st phase
Motor stall torque correction factor
Motor pole position identification current
Speed at start of field weakening
Cable resistance cold
Motor series inductance
Current controller adaptation, starting point KP adapted
Current controller adaptation, starting point KP adapted
Current controller adaptation P gain adaptation
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3