Siemens SINAMICS S120 Commissioning Manual page 223

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

● p4601[0..n]-p4603[0..n]: Select the temperature sensor type of temperature channels 2-4,
● Parameter r4620[0...3] Motor temperatures SME
Diagnostic parameters r0458[0...2] Sensor Module properties
Index [0...2]: Encoder 1...encoder 3
Parameter r0458 allows the following properties to be queried at the temperature sensor
modules:
Selection of several temperature channels p4601 ... p4603 is only possible, for example,
when parameter p0601 = 10 is set. This can be checked using the entry r0458.8 = 1.
You can find further information on parameter r0458 in: SINAMICS S 120/S150 List Manual.
Active Line Module, Basic Line Module, Smart Line Module, Motor Module (chassis)
Parameter p0601 "Motor temperature sensor type" enables the setting for the sensor type for
the temperature measurement at input X21 (booksize) or X41 (chassis). The measured
value is displayed in r0035.
Commissioning Manual
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
depending on encoder data set n.
Only temperature channels 2-4 are available at terminal X200.
is used to display the current temperatures in the motor, measured via an SME120 or
SME125. The indices mean:
[1] = SME temperature channel 2 / motor temperature sensor 2
[2] = SME temperature channel 3 / motor temperature sensor 3
[3] = SME temperature channel 4 / motor temperature sensor 4
Bit
Feature
02
Temperature sensor connection present
03
Connection for PTC for motors with DRIVE-CLiQ also present
04
Module temperature available
08
Evaluation set up across several temperature channels
2.16 Temperature sensors for SINAMICS components
Commissioning
221

Advertisement

Table of Contents
loading

Table of Contents