Topology example: Drives in vector control

Example 1
A drive line-up with three Motor Modules in chassis format with identical pulse frequencies or
three Motor Modules in booksize format in vector control mode.
The Motor Modules chassis format with identical pulse frequencies or the Motor Modules
booksize format in vector control mode can be connected to one DRIVE-CLiQ interface on
the Control Unit.
In the following diagram, three Motor Modules are connected to the DRIVE-CLiQ socket
X101.
Note
The offline topology automatically generated in the STARTER commissioning tool must be
manually modified, if this topology was wired.
Figure 1-6
Commissioning Manual
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
Drive line-up (chassis) with identical pulse frequencies
Preparation for commissioning
1.5 Rules for wiring with DRIVE-CLiQ
45