Smart Line Modules Booksize 5 Kw And 10 Kw - Siemens SINAMICS S120 Commissioning Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

3.1.2.3

Smart Line Modules booksize 5 kW and 10 kW

Table 3- 17
Meaning of the LEDs at the Smart Line Modules 5 kW and 10 kW
LED
Color
READY
Green
Yellow
Red
DC LINK
Yellow
Red
Risk of electric shock as a result of the high DC link voltage
Hazardous DC link voltages may be present at any time regardless of the state of the "DC
link" LED.
Note the warning information on the component!
Commissioning Manual
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
State
Description, cause
Off
Electronic power supply is missing or outside
permissible tolerance range.
Continuous
Component is ready to operate.
light
Continuous
Pre-charging not completed.
light
Bypass relay dropped out
EP terminals not supplied with 24 VDC.
Continuous
Overtemperature
light
Overcurrent
Off
Electronic power supply is missing or outside
permissible tolerance range.
Continuous
DC link voltage within permissible tolerance range.
light
Continuous
DC link voltage outside permissible tolerance range.
light
Line supply fault.
WARNING
Diagnostics
3.1 Diagnostics via LEDs
Remedy
Diagnose fault (via output
terminals) and
acknowledge it (via input
terminal)
Check the line voltage.
251