Technical Instructions
Document No. LV5-1000
Function Address Number
Data designation
of words
03/04
80, 81
2
Fuel volume oil (read only)
(resettable from AZL5... version V4.10)
0...199999999.9 l
0...199999999.9 gal
03/04
82
1
Number of lockouts
03/04
83
1
Extra temperature sensor
(from AZL5... version V4.10 or later)
Parameters 84...137 are available on AZL5... version V4.20 or later
03/04
84-91
8
AZL5... ASN
03/04
92
1
AZL5... parameter set code
03/04
93
1
AZL5... parameter set version
03/04
94-96
3
AZL5... identification date
03/04
97
1
AZL5... identification number
03/04
98-105
8
Burner control ASN
03/04
106
1
Burner control parameter set code
03/04
107
1
Burner control parameter set version
03/04
108-110 3
Burner control identification date
03/04
111
1
Burner control identification number
03/04
112
1
Software version AZL5...
03/04
113
1
Software version burner control
03/04
114
1
Software version load controller
03/04
115-122 8
Burner identification
03/04
123
1
Min-output gas
03/04
124
1
Max-output gas
03/04
125
1
Min-output oil
03/04
126
1
Max-output oil
R 03/04
127
1
Load limitation enduser (modulating)
W 16
R 03/04
128
1
Load limitation enduser (multistage)
W 16
03/04
129
1
Temperature limiter switching differential ON
(in address 29: Temperature limiter OFF
threshold, in degrees Celsius / Fahrenheit)
03/04
130
1
Measuring range temperature sensor
03/04
131
1
Adaption active / inactive
03/04
132
1
Adaption state
R 03/04
133
1
Start adaption
W 16
R 03/04
134
1
Adaption output
W 16
Permissible values: 40%, 50%, 60%,
70%, 80%, 90%, 100%
R 03/04
135
1
P-value
W 16
R 03/04
136
1
I-value
W 16
Section 8
Access
Data
Data type /
format
coding
R/W*
S32
EEPROM
R
U16
R
U16
°C:
°F:
R
U8[16] String
R
U16
R
U16
R
U16[3] Date
R
U16
R
U8[16] String
R
U16
R
U16
R
U16[3] Date
R
U16
R
U16
Hexadecimal
R
U16
Hexadecimal
R
U16
Hexadecimal
R
U8[16] String
R
U16
Fire rate
R
U16
Fire rate
R
U16
Fire rate
R
U16
Fire rate
R/W*
U16
Fire rate
EEPROM
R/W*
U16
0: S1
EEPROM
1: S2
2: S3
R
S16
Percent
R
U16
0: 150°C / 302°F
1: 400°C / 752°F
2: 850°C / 1562F
R
U16
0: Inactive
1: Active
R
U16
Adaption list
R/W
U16
0: Reset value
1: Start
2: Abort
R/W*
U16
Percent
EEPROM
R/W*
U16
Percent
EEPROM
R/W*
U16
Seconds
EEPROM
Page 8
HOME
LMV Series
Range
Updating
rate
See "Data types"
Slow
on page 10
0...65535
Slow
0..2000 °C
Slow
32..3632 °F
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Upon
reset
0...100 %
Slow
0...100 %
Slow
0...100 %
Slow
1001...1003
0...100 %
Slow
1001...1003
0...100 %
Slow
0...2
Slow
-50...0 %
Slow
0...2
Slow
0...1
Fast
0...12
Slow
0...2
Slow
40...100 %
Slow
2...500 %
Slow
0...2000 s
Slow
SCC Inc.