Figure 3 - 21
The Multistretch
Screen
STATE 1
ZERO TRIM
GAIN
FILM TENSION
HALL EFFECT SENSOR
MODIFY SETTINGS
APPLY SETTINGS
Page 3-28
This is the Multistretch Settings (MIB) screen. This page is useful primarily to repair per-
sonnel when troubleshooting the machine.
Table 3-20. The Multistretch Screen Button Descriptions
Press this button to modify the Zero Trim datapoint, in terms of milliamps. This
value determines at which point the Multistretch will begin paying out film as the
dancer bar is deflected. This value should be .5 mA higher than the Hall Effect Sen-
sor reading with the dancer bar at rest. Min - 3.mA Max - 8 mA
Press this button to modify the Gain datapoint, in terms of percentage. This value
sets percentage of deflection of the dancer bar that is required for the Multistretch to
pay out film at maximum speed. Min - 10% Max - 100%
Press this button to modify the Film Tension datapoint, in terms of percentage. This
value limits the maximum speed at which the Multistretch will pay out film, which
creates tension. Min - 0% Max - 100%
This displays the current dancer bar Hall Effect Sensor reading, in terms of milli-
amps.
Press this button for access to modify the Zero Trim or Gain datapoints.
The Multistretch is disabled while modifying the datapoints.
Press this button to accept the current Zero Trim and Gain datapoints and apply
them to the Multistretch. When complete, the drive will be enabled again.