Troubleshooting
PROBLEM
Turntable / Tower
Rotation-
Turntable / Tower Will Not
Stop In The Correct Position.
(Table Does Stop At End Of
Cycle-but In Wrong Position
Page 4-2
Table 4-1. Troubleshooting Chart (Continued)
POSSIBLE CAUSE
Turntable end of cycle positioning
counter value is set incorrectly.
Observe the Turntable end of
cycle positioning counter value on
the HMI.
Slow Down Position for Tower /
Turntable Timer is adjusted too
high. Observe the Slow Down
Position for Tower /Turntable
Timer value on the HMI.
Table / Tower preset speeds are
set incorrectly. The table / turnta-
ble is overhauling and the drive
can not stop the load fast enough.
Check the value of the SP-2-SP-3
and SP-4 parameters on the Table
/ Tower VFD. Ensure that they are
set within correct values.
Table / Tower deceleration value
is set incorrectly. The table / turn-
table is overhauling and the drive
can not stop the load fast enough.
Check the value of the DEC
parameter on the Table / Tower
VFD. Ensure that it is set within
the Orion factory default values.
Component failure.
SOLUTION
Refer to the factory default settings value
list.
Refer to the factory default settings value
list.
Refer to the factory default settings value
list.
Refer to the factory default settings value
list.
Check error message on the Table / Tower
VFD display.
Refer to the supplied VFD user manual for
error message. Replace if needed.