Pro Mach Orion CTS Flex Stretchwrapper Manual page 79

Stretch-wrapping equipment
Table of Contents

Advertisement

Orion
Revision 3.0
25 July 2016
Table 3-32. The Information and Alarm Displays (Continued)
MESSAGE
CLAMIPING &
CUTTING FILM
INITIALIZING
LIGHT CURTAIN
BLOCKED
SAFETY SYSTEM NOT
READY
FAULTS EXIST
CARRIAGE MOVING
UP TOO SLOWLY
CARRIAGE MOVING
DOWN TOO SLOWLY
BRUSH AND CUTTER
NOT HOME
MULTISTRETCH VFD
NOT READY
MAIN DRIVE VFD NOT
READY
CARRIAGE VFD NOT
READY
DESCRIPTION
The machine is now in the clamp and cut cycle.
The machine is initializing.
The light curtain is blocked (if equipped.)
The safety controller is not ready to run.
Faults currently exist.
The carriage is moving upward too slowly.
The carriage is moving downward too slowly.
The brush and cutter are not home.
The indicated VFD is not ready to run.
Machine Manual
CTS Flex Stretchwrapper
System Operation
CORRECTION
This is for informational pur-
poses only. No correction neces-
sary.
There is a brief initialization
sequence once the machine is
reset. Allow the machine to ini-
tialize prior to starting.
Clear the obstruction from the
light curtain to allow operation.
Allow the safety system to ini-
tialize prior to running.
Correct the cause of the fault.
Press reset to reset the fault con-
dition once the cause is cor-
rected.
Check for the cause of the car-
riage not moving correctly.
Check the belt drive behind the
back panel. Check for a jam or
obstruction on the track.
Check for the cause of the car-
riage not moving correctly.
Check the belt drive behind the
back panel. Check for a jam or
obstruction on the track.
Cycle the brush and cutter.
Check why the brush and cutter
can't reach the home position.
Check the fault code on the VFD
display in the electrical cabinet.
See VFD manual for fault code
information.