Timers Screen; The Timers Screen - Pro Mach Orion CTS Flex Stretchwrapper Manual

Stretch-wrapping equipment
Table of Contents

Advertisement

Orion
Revision 3.0
25 July 2016

Timers Screen

Figure 3 - 17

The Timers Screen

STATE 1
AUTOHEIGHT DELAY
TENSION ENGAGE
DELAY
FILM FAULT DELAY
CLAMP CLOSE DELAY
This is the Timers Screen. This screen allows adjustment of the timers involved in the
machine cycle. See the Table below for descriptions and parameters of each setting.
Table 3-16. The Timers Screen Button Descriptions
Press this button to modify the Autoheight Delay value, in terms of milliseconds.
This value determines the amount of time that the Carriage will continue to travel
up during the wrap cycle after the Autoheight photoeye no longer detects a load.
This is used to adjust the amount of overlap on the top of the load. Min - 0 ms Max
- 10000 ms
Press this button to modify the Tension Engage Delay value, in terms of millisec-
onds. This value determines the amount of time, at the beginning of the wrap cycle,
that the Multistretch will pay out film at normal speed before applying tension. This
is to keep film from pulling out of the clamp or away from the load. Min - 0 ms Max
- 10000 ms
Press this button to modify the Film Fault Delay value, in terms of milliseconds.
This value determines the amount of time, during a wrap cycle, that the Multistretch
must be inactive before triggering an End of Film Roll or Broken Film fault. Min - 0
ms Max - 10000 ms
Press this button to modify the Clamp Close Delay value, in terms of milliseconds.
This value determines the amount of time, after the Main Drive has reached the End
of Cycle position, that the machine will delay before initiating the Clamp and Cut
sequence. Min - 0 sec Max - 3 sec