Machine Manual
CTS Flex Stretchwrapper
Introduction and Safety
Pneumatic and Vacuum Systems
Page 1-10
To avoid hazards of moving mechanisms, pinch points and other personal injuries, the
main compressed air supply valve for the system shall be locked out & tagged as a safety
precaution during entry and maintenance to the system.
1. To accomplish this, turn the Main Air Supply valve to the "OFF" position and install a
personal locking device through the padlock hole on the valve handle.
2. Also attach a Danger tag to the handle containing a statement prohibiting unautho-
rized operation of the disconnect and removal of the tag signed by the individual
responsible for locking out the system.
If several personnel are performing maintenance, each individual shall install a lockout
device and tag. Qualified personnel shall vent any stored or accumulated air in pneumatic/
vacuum devices before working on them. Check appropriate equipment manuals on exact
procedures.
To re-supply compressed air to the equipment, a qualified person shall conduct visual
inspections, as necessary, to verify that mechanisms are properly connected, as well as all
tools and other objects have been removed so that equipment can safely operate. Personnel
exposed to pneumatic/vacuum hazard areas shall be warned to stay clear of equipment.
Each lock and tag shall be removed by the person who applied it, or, under their direct
supervision. A visual determination that all personnel are clear of the equipment shall be
accomplished before the main air supply valve is turned to the "ON'' position.
Orion
Revision 3.0
25 July 2016