PROBLEM
Turntable / Tower Will Not
Rotate
Table 4-1. Troubleshooting Chart (Continued)
POSSIBLE CAUSE
No control Power / E-Stop Condi-
tion.
Machine is in Cycle Pause.
VFD parameter settings are incor-
rect.
Blown Fuse.
VFD Error.
Open circuit to the motor.
Motor Failure.
CTS Flex Stretchwrapper
SOLUTION
E-Stop button is Flashing or Green Start
button is not illuminated.
Perform E-Stop Reset (pull E-Stop button
to the out position then press the Green
Start button so that it is Illuminated. Press
Cycle reset on the Touchscreen.
Observe the Cycle Pause Icon on the Run
Screen. If it is illuminated, the machine is
in a Pause state.
Press Resume to resume wrapping.
Review the parameter settings in the VFD.
Refer to the supplied VFD Manual for
procedure.
Refer to the VFD manual and the Orion
parameter settings sheet supplied with the
machine for maximum frequency settings.
Locate Table / Tower rotation control
fuse. Remove fuse and check continuity.
Bad Fuse? Replace with correct type.
Check the status of the table / tower motor
controller (VFD) for error message.
Refer to the VFD manual supplied with
the machine for error messaging solutions.
Check wire continuity from VFD to
Motor.
Repair or replace open wiring.
Perform motor test per motor manufac-
turer's recommendations.
Replace Motor as needed.
Machine Manual
Troubleshooting
Page 4-5