System Operation
Table 3-33. The Information and Alarm Displays (Continued)
MESSAGE
LOW AIR PRESSURE
BRUSH AND CUTTER
NOT HOME
OBSTACLE DETECTED
MULTISTRETCH VFD
NOT READY
MAIN DRIVE VFD NOT
READY
CARRIAGE VFD NOT
READY
(NAME) CONVEYOR
VFD NOT READY
X2X
COMMUNICATION
ERROR
RS485
COMMUNICATION
ERROR
Page 3-52
DESCRIPTION
The machine pneumatic pressure is low.
The brush and cutter are not home.
The tower has an obstruction.
The indicated VFD is not ready to run.
There is an X2X communication fault, press and
release the E-stop button to clear the fault.
There is an RS485 communication fault, press
and release the E-stop button to clear the fault.
Revision 3.0
25 July 2016
CORRECTION
Check the pneumatic supply.
Ensure 80 PSI is available.
Cycle the brush and cutter.
Check why the brush and cutter
can't reach the home position.
Check for a mechanical bind.
Clear the cause of the fault.
Reset and restart, when ready.
Check the fault code on the VFD
display in the electrical cabinet.
See VFD manual for fault code
information.
Contact Orion Packaging if
problem persists.
Contact Orion Packaging if
problem persists.