STATE 1
AUTOHEIGHT DELAY
FILM FAULT DELAY
Page 3-28
This is the Timers Screen. This screen allows adjustment of the timers involved in the
machine cycle. See the Table below for descriptions and parameters of each setting.
Press this button to modify the Autoheight Delay value, in terms of milliseconds.
This value determines the amount of time that the Carriage will continue to travel
up during the wrap cycle after the Autoheight photoeye no longer detects a load.
This is used to adjust the amount of overlap on the top of the load. Min - 0 ms Max
- 10000 ms
Press this button to modify the Film Fault Delay value, in terms of milliseconds.
This value determines the amount of time, during a wrap cycle, that the Multistretch
must be inactive before triggering an End of Film Roll or Broken Film fault. Min - 0
ms Max - 10000 ms