Additional Resources; Definitions - Danfoss VLT Compressor Drive CDS 803 Design Manual

Hide thumbs Also See for VLT Compressor Drive CDS 803:
Table of Contents

Advertisement

Introduction
1
1
PCB
PELV
Regen
RPM
s
T
LIM
U
M,N
V
Table 1.2 Abbreviations

1.5 Additional Resources

®
VLT
provides basic information on mechanical
dimensions, installation and programming.
®
VLT
Guide provides information on how to program
and includes complete parameter descriptions.
®
VLT
entails all technical information about the
frequency converter and customer design and
applications.
MCT 10 Set-up Software enables the user to
configure the frequency converter from a
Windows
Danfoss technical literature is available in print from a local
Danfoss Sales Office or at:
vlt-drives.danfoss.com/Support/Technical-Documentation/

1.6 Definitions

Frequency converter
I
VLT,MAX
The maximum output current.
I
VLT,N
The rated output current supplied by the frequency
converter.
U
VLT, MAX
The maximum output voltage.
Input
The connected compressor
can start and stop with LCP
and the digital inputs.
Functions are divided into 2
groups.
Functions in group 1 have
higher priority than
functions in group 2.
Table 1.3 Control Commands
Compressor
f
JOG
The motor frequency when the jog function is activated
(via digital terminals).
6
Printed circuit board
Protective extra low voltage
Regenerative terminals
Revolutions per minute
Second
Torque limit
Nominal motor voltage
Volts
Compressor Drive CDS 803 Quick Guide
Compressor Drive CDS 803 Programming
Compressor Drive CDS 803 Design Guide
based PC environment.
Group
Reset, coasting stop, reset
1
and coasting stop, quick-
stop, DC braking, stop,
and the [Off] key.
Start, pulse start,
Group
reversing, start reversing,
2
jog, and freeze output
Danfoss A/S © 12/2015 All rights reserved.
®
VLT
Compressor Drive CDS 803
f
M
The motor frequency.
f
MAX
The maximum compressor frequency.
f
MIN
The minimum compressor frequency.
f
M,N
The rated motor frequency (nameplate data).
I
M
The motor current.
I
M,N
The rated motor current (nameplate data).
n
M,N
The nominal motor speed (nameplate data).
P
M,N
The rated motor power (nameplate data).
U
M
The instant motor voltage.
U
M,N
The rated motor voltage (nameplate data).
Break-away torque
Torque
Illustration 1.1 Break-away Torque
η
VLT
The efficiency of the frequency converter is defined as the
ratio between the power output and the power input.
Start-disable command
A stop command belonging to the group 1 control
commands, see Table 1.3.
Stop command
See control commands, Table 1.3.
References
Analog reference
A signal transmitted to the analog inputs 53 or 54, can be
voltage or current.
Pull-out
rpm
MG18N202

Advertisement