List of ACU events
Error
ACU
code
Severity
PCB
(ID)
09000-0 KDM ERROR
09001-0 KDM ERROR
09002-0 KDM ERROR
09010-0 KDM ERROR
0B000-0 PSM
ERROR
0B001-0 PSM
ERROR
0B010-0 PSM
ERROR
0B060-0 PSM
WARNING NMEA 0183 parse
0B061-0 PSM
WARNING Power supply
B-12
Description
KDM 3V3 supply
KDM 12V supply
KDM display
KDM link/SW
version
PSM production
data
NMEA 2000
identifier
PSM link/SW
version
error
temperature
Table B-2: ACU event messages (Continued)
Explanation
Internal 3V3 voltage supply error in the KDM.
Internal 12V voltage supply error in the KDM.
Display hardware error in the KDM.
Link to the KDM module could not be
established. Either the KDM board is
malfunctioning, or - if the system software has
just been updated - the software is too old and is
not compatible with the KDM hardware.
Missing or invalid production data in the PSM. It
should be replaced.
Missing or invalid production data in the PSM. It
should be replaced.
Link to the PSM module could not be
established. Either the PSM board is
malfunctioning, or - if the system software has
just been updated - the software is too old and is
not compatible with the PSM hardware.
Parse errors detected on the NMEA 0183
interface. Check NMEA 0183 cable, signal
levels etc.
ACU Power supply temperature is high. Improve
ventilation or move to a cooler area. Info:
00000000 = Temperature warning, system still
operational, but will shut down eventually if
temperature keeps rising. 00000001 =
Temperature critical, system has shut down to
protect the hardware from overheating.