Furuno FV-110GX Operator's Manual page 145

Gx terminal
Table of Contents

Advertisement

Error
Unit
code (ID)
0A018-0
Antenna ERROR
0A019-0
Antenna ERROR
0A01A-0 Antenna ERROR
0A01E-0 Antenna ERROR
0A021-0
Antenna ERROR
0A022-0
Antenna ERROR
0A023-0
Antenna ERROR
0A025-0
Antenna ERROR
0A028-0
Antenna ERROR
0A029-0
Antenna ERROR
Severity
Description
ISM ABS
device
PMM ABS
device
BCM ABS
device
Sensor sanity
Azi axis
calibration
Xel axis
calibration
Ele axis
calibration
Antenna
calibration
Demodulator
load
XIM PLL lock
Table B-1: ADU event messages (Continued)
Explanation
Cannot initialise the ISM Info:
0x00000000: Device not found (possible
cabling problem)
0x000cbbaa: Device internal error (replace
device) aa=status, bb=state, c=calibration data
error.
Cannot initialise the PMM. Info: See 0A015-0.
Cannot initialise the BCM. Info: See 0A015-0.
Too many invalid values measured by the ISM
during initialisation. Check for vibrations or
malfunctioning ISM.
Azimuth axis zero reference not found. Check
belt and zero reference module. Info:
0x00000001: Timeout (operation did not
complete in time)
0x00000010: Encoder or mechanical problem
0x00000020: Zero reference not found
0x00000040: End stop not found.
Cross-elevation axis zero reference or end
stops not found at expected locations. Check
belt, zero reference module, and end stops.
Info: See 0A021-0.
Elevation axis zero reference or end stops not
found at expected locations. Check belt, zero
reference module, and end stops. Info: See
0A021-0.
One or more errors occurred during antenna
start-up Info:
0x00000001: Timeout (calibration did not
complete in time)
0x00000010: Azimuth axis
0x00000020: Cross-elevation axis
0x00000040: Elevation axis
0x00000080: Polarisation axis
The second receiver demodulator cannot be
initialised and loaded correctly.
The PLL on the VIM/TIM does not lock.
List of ADU events
B-3