List Of Acu Events - Furuno FV-110GX Operator's Manual

Gx terminal
Table of Contents

Advertisement

List of ACU events

B.3
List of ACU events
Error
ACU
code
Severity
PCB
(ID)
08060-0 ADM WARNING Antenna modem
08063-0 ADM ERROR
08064-0 ADM ERROR
08065-0 ADM WARNING GNSS data
08066-0 ADM WARNING Heading data
08067-0 ADM ERROR
08068-0 ADM ERROR
08069-0 ADM WARNING Blocking Zone
0806A-0 ADM WARNING VMU connection
0806C-0 ADM ERROR
0806D-0 ADM ERROR
0806E-0 ADM ERROR
B-8
Description
ACU/Antenna communication error detected
(framing and parity). If the situation is persistent,
check if cable specifications comply (length and
attenuation).
Antenna connection The ACU has lost connection with the antenna.
ADM PLL lock
The intermediate frequency PLL is not in lock.
Check the 10 MHz reference signal.
Missing GNSS data (fix).
Missing heading information. Check cable and
heading provider device.
PCB temperature
ADM temperature too high. Make sure there is
compliance with the environmental
specifications.
PSM power
The PSM fails to provide the requested supply
voltage.
The antenna has entered a blocking zone.
The ACU has lost connection with the sat
modem.
VMU frequency
There is a mismatch in the frequency setup.
setup
Probably the sat modem is not configured
correctly to match the requirements of the ACU
and antenna. A common mismatch is the absence
of Rx or Tx LO parameter in the VSAT modem.
Antenna power
The antenna supply voltage is outside the
allowed limits. This may happen if the PSM fails
to provide the requested supply voltage.
VMU reference
There is no VMU Rx or Tx reference signal.
signal
Whether this is Rx or Tx reference depends on
the user's selection on the modem profile page in
the web interface. Make sure VMU Rx/Tx cable
is connected and that the VMU is configured to
output the RX/TX reference signal.
Table B-2: ACU event messages
Explanation

Advertisement

Table of Contents
loading

Table of Contents