Furuno FV-110GX Operator's Manual page 146

Gx terminal
Table of Contents

Advertisement

List of ADU events
Error
Unit
code (ID)
0A02B-0 Antenna ERROR
0A02D-0 Antenna ERROR
0A034-0
Antenna WARNING ACU
0A035-0
Antenna WARNING ISM data valid
0A036-0
Antenna WARNING ISM data range
0A037-0
Antenna WARNING GNSS
0A038-0
Antenna WARNING GNSS data
0A039-0
Antenna WARNING GNSS device
0A03A-0 Antenna WARNING GNSS device
0A03B-0 Antenna ERROR
0A03C-0 Antenna ERROR
0A03D-0 Antenna ERROR
0A03E-0 Antenna ERROR
0A03F-0 Antenna WARNING AMB timing
B-4
Severity
Description
ABS software
version
BUC reference
switch
communication
communication
range
warning
error
Azi DDM
shutdown
Xel DDM
shutdown
Ele DDM
shutdown
PMM shutdown As Azi DDM shutdown but detected by the
Table B-1: ADU event messages (Continued)
Explanation
The ABS software version in the antenna is too
old to match the hardware requirements.
Upgrade the software.
The BUC reference switches do not work.
Check PCM-VIM cable and replace cable,
VIM or PCM.
The communication link between ACU and
antenna is down.
Sensor measurements from the ISM are
invalid. This indicates a malfunctioning ISM.
Sensor measurements from the ISM are out of
range.
Lost connection to the GNSS device.
Received information from the GNSS device
which is out of range.
Local GNSS device warning.
Local GNSS device error.
The azimuth motor control has detected one of
the following situations: Extreme temperature,
voltage, current or velocity. The motor was
then shut down. This is usually a temporary
situation and is probably fixed by a restart of
the system.
As Azi DDM shutdown but detected by the
cross-elevation motor control.
As Azi DDM shutdown but detected by the
elevation motor control.
polarisation motor control.
This indicates a busy situation. It may occur
during installation procedures. No user
interaction is required.