External Output

The outputs are potential-free. The relay is designed for 24V. Relay output: max 24 V
and max. 100 mA.. Standard: Closing contact.
Connection
15-pole Sub-D-socket.
Input
NPN input, can be changed to PNP via software.
Standard
NPN (to GND switching)
Input voltage for PNP
10 V...24 V
72800153 Markoprint XB4JET / XB8JET
PIN
Name
1
Out 5
2
Out 5
3
Out 6
4
Out 6
5
Out 7
6
Out 7
7
Out 8
8
Out 8
9
max.100
mA
10
11
In 1
12
In 2
13
In 5
14
In 6
15
NC
Seite 132 von 162
Description
Potential
Relay 1
OK
Relay 1
Relay 2
Warn
Relay 2
Relay 3
Alarm
Relay 3
Relay 4
Reserve
Relay 4
24V internal
+24 V
GND
0 V
Input 1
Input 2
Input 5
Input 6
GB