Plugs And Sockets; Sensor - Weber Markoprint XB4JET Manual For Installation, Operation And Maintenance

Table of Contents

Advertisement

Appendix

Plugs and sockets

In the Markoprint XB4JET/XB8JET all interfaces inputs and outputs are available 2 times

Sensor

Sensor input: 24V
Standard: NPN (switching to GND)
Can be changed to PNP via software
Photocell with 4-pole M8 round plug
The PIN2 can optionally be used as an additional input. This must be programmed
customer-specifically.
Standard is the inverse output by many sensors. The input can selected as sensor 1+2
inverted in the menu.
Signal threshold 12V +- 2V
PIN
Description
1
Power
2 – Sen2 Start pulse (inverted signal)
3
GND
4 – Sen1 Start pulse
Seite 128 von 162
72800153 Markoprint XB4JET / XB8JET
Value
+ 24
Input standard NPN
0
Input standard NPN
Unit
V
-
V
-
GB