Figure 12 Attaching an air filter to an M9010/M9010-GM gateway
TIP:
• Install the power cord management bracket before you install an air filter for the M9010 or
M9010-GM gateway.
• Clean the air filter every three months to ensure correct ventilation and heat dissipation of the
gateway.

Mounting the gateway in the rack

WARNING!
To avoid device damage or even bodily injury, do not hold the handle of a fan tray or power module,
air vents, or the handle on the rear panel of the chassis to move the gateway.
To mount the gateway in the rack:
Move the chassis to face the rear of the chassis towards the front of the rack.
1.
Use at least two people to lift the gateway by using the chassis handles or supporting the
2.
bottom of the chassis until the bottom of the gateway is a little higher than the slide rails on the
rack.
As a best practice, use a mechanical lift for moving your gateway.
Place the gateway on the slide rails and slide the gateway along the slide rails until the
3.
mounting brackets on the gateway touch the front rack posts, as shown in
After placing the switch on the slide rails, do not leave go of your hands immediately because
this might tip the switch, damaging the switch or even causing bodily injury.
15
Figure
13.