Figure 13 Placing the chassis on the rack (M9006)
Use the screws to attach the mounting brackets to the rack.
4.
If the mounting holes in the mounting brackets cannot align with the cage nuts on the rack,
verify that the bottom edge of the slide rail aligns with the middle of the narrower metal area
between holes and that the cage nuts are installed in the correct holes.
Figure 14 Securing the chassis to the rack (M9006)

Grounding the gateway

CAUTION:
• Before you use the gateway, ground the gateway correctly.
• Use the grounding cable (yellow-green grounding cable) that comes with your gateway.
• Make sure the grounding terminal of the rack is connected to the grounding strip in the equipment
room. Do not connect it to a fire main or lightning rod.
To ground the gateway:
Remove the grounding screws from the grounding holes at the rear of the chassis.
1.
16