Figure 3-2 Rack-mounting the SecPath V100-S

3.3 Connecting the Grounding Cable

Caution:
Before installing or using your security gateway, properly connect the grounding cable
to protect the device against lightning and other interference sources.
The SecPath V100-S provides on its rear panel a grounding screw (with a grounding
symbol, see Figure 1-2), which must be grounded properly to safely channel the faradic
current and leakage current to the ground and to make the device less susceptible to
electromagnetic interference (EMI).
Connect this screw to the ground using a PGND cable. The grounding resistance
should not be greater than 5 ohm. If the security gateway is mounted in a 19-inch rack,
the rack should also be connected to the ground.
Caution:
Lightning strikes may damage your security gateway and the connected device as well.
For secure lightning protection, make sure that your security gateway has been
grounded properly during its operation.
Chapter 3 Installing the SecPath V100-S
(2)
(2) Rack-mounting ear
3-3