2. Commissioning
2.2

Commissioning on the DeviceNet

2.2.1 General information

2−6
Please note
The Festo valve terminal type CDVI−DN can be used on
all DeviceNet masters.
This chapter describes configuration and commissioning
using the example of the Allen−Bradley controlllers.
If the CDVI valve terminal is used on the DeviceNet, the
following special features must be observed:
The I/O addresses of all recognized DeviceNet slaves can
be assigned freely as M−file addresses or as discrete I/Os
in the Scanlist.
The address assignment of a network slave is usually
carried out in ascending sequence.
The input and output addresses can be assigned indepen
dently of each other.
Please note
Assign the I/O addresses of the network slaves so that
there is sufficient reserve for later extensions.
The following sections contain general valid instructions on
configuring a valve terminal on the DeviceNet.
Detailed information can be found in the documentation or
the Help for the configuration program you are using.