Connect The Power Supply Of The Valve Terminal - Festo CDVI-DN Series Electronic Manual

Valve terminal
Table of Contents

Advertisement

1. Installation

1.4.4 Connect the power supply of the valve terminal

Festo P.BE−CDVI−DN−EN en 0404NH
Use only a 5−pin M12 socket for the power supply (A−coded;
see appendix: Accessories) and connect this only to the con
nection for the power supply (see also Fig. 1/1).
Pin assignment of the power supply connection
24 V DC operating voltage for the electronics (and input
1.
modules on the CP string)
24 V DC load voltage for the valves (and outputs)
2.
0 V electronics (and output modules on the CP string)
3.
0 V load voltage for valves (and outputs)
4.
Earth/ground connection
5.
Fig. 1/6: Pin assignment of the power supply connection
Please note
Extending the CDVI−DN with a CP valve terminal of the 1st.
generation (without additional supply):
Provide a bridge between pins 3 and 4.
·
However, there will then no longer be electrical isolation
between the electronics voltage and the load voltage
(valves).
1−21

Advertisement

Table of Contents
loading

Table of Contents