2. Commissioning
2−26
orientated, only the transition from value 0" to value 1" will
reset the Condition Counter Value".
With the parameter Condition Counter Preselection" you can
define a limit value for each counter. If this limit value is ex
ceeded, the parameter Condition Counter Status" will be set.
In addition to the individual Condition Counter Status", all
comparison results are grouped together in the parameter
Status Condition Counter ...".
With the value 0" in the Condition Counter Preselection"
the compare function becomes inactive (standard setting).
Example
Fig. 2/14: Example of parametrizing the Condition Counter"
with RSNetWorx
Festo P.BE−CDVI−DN−EN en 0404NH