B. DeviceNet objects
B.1.5 Festo Discrete Output Object: Class Code 100d
Attributes Access
3
Get/Set
5
Get/Set
6
Get/Set
7
Get/Set
8
Get/Set
B.1.6 Festo Discrete Input Object: Class Code 101d
Attributes
Access
3
Get
B−6
Each instance has 16 bits.
Name
Type
Output value
INT
Fault Action
INT
Fault Value
INT
Idle Action
INT
Idle Value
INT
Instance 1: For one CP input module
Name
Type
Input value
INT
Description
Value of the output (0/1)
Parameter value:
0 = The status of the output is defined by
the Fault Value" (0/1)
1 = The status of the output is frozen
Defines the status of the output in Fault
Mode, if Fault Action is set to = 0.
Parameter value:
0 = The status of the output is defined by
the Idle Value" (0/1)
1 = The status of the output is frozen
Defines the status of the output in Idle
Mode, if Idle Action is set to = 0.
Description
Input value of the input module (0/1)
Festo P.BE−CDVI−DN−EN en 0404NH