Festo CDVI-DN Series Electronic Manual page 34

Valve terminal
Table of Contents

Advertisement

1. Installation
1
Cable
2
Strain relief
3
Housing
4
Connector part
Fig. 1/7: Individual plug parts and cable routing
Preparing
1−22
Fitting the connector socket
1
4
When you have selected suitable cables, connect them as
follows (Fig. 1/7):
1. In order to open the plug, loosen the centre knurled nut.
2. Open the strain relief at the rear of the housing. Then
pass the cable through.
3. Remove 5 mm of the insulation from the ends of the
conductor and fit end sleeves on the strands.
4. Connect the ends of the conductor.
5. Replace the connector part on the housing of the socket.
Pull the cable back so that there are no loops inside the
housing.
6. Tighten the strain relief.
Festo P.BE−CDVI−DN−EN en 0404NH
2
3

Advertisement

Table of Contents
loading

Table of Contents