6.
3.4

Prerequisites for an EN-conform Setup of the System

Instructions to modify the IUI-AMAX-LED8 and the IUI-AMAX-LCD8 Keypad to meet the EN
requirements
1.
2.
3.
Figure 3.2
4.
(See Figure 3.3 and Figure 3.4).
The Adhesive must be applied to the Window and to the Enclosure
Figure 3.3
Bosch Sicherheitssysteme GmbH
If the LED on the control panel PCB does not fast flash, the factory default was
unsuccessful.
System must be mounted inside the monitored area on a stable surface.
Keypads must be mounted to the inner side of the monitored area.
Once the system is tested and ready to use, Enclosure Door and Keypads must be
secured with screws.
Two external Warning Devices must be connected to the System.
The Dialer must be connected to a Central Monitoring Station.
A 12V/7AH Battery must be connected to the System.
The Maximum Current of all Components together (PCB=lOOmA, lCP-KP8L=18mA,
ICPKP8 =24mA) should not exceed 550mA.
The lock can only be used in an non EN setup.
The panel must be programmed with the EN settings indicated on the programming
sheet. When the panel is set without EN parameters, the EN Indication (Label) must be
removed.
Open the Keypad.
Remove the PCB (open the two screws on the PCB).
Remove the rubber.
Apply one drop of Instant Adhesive Loctite 401 on each side of the window
Installation Manual
Installation | en
17