en | System Informations 2
1.
2.
3.
9- Fire Zone
The Fire zone will perform as below:
1.
2.
3.
10- External Fault Zone
The Fault Zone/Input will perform as below:
1.
2.
3.
11- Bolt Contact Zone
The Bolt-Contact zone will perform as below:
1.
2.
F.01U.241.127 | V4 | 2011.12
Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
STAY Arm: Same as AWAY Arm performance.
A Tamper zone does not send a restore report until the zone is restored.
Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
STAY Arm: Same as AWAY Arm performance.
A Fire zone does not send a restore report until the zone is restored.
Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
STAY Arm: Same as AWAY Arm performance.
The restore report will only be sent when the zone is restored and fault is reset.
Disarm:
Zone normal - no Alarm / no report
Zone triggered - no Alarm / no report
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - no Alarm / no report
Zone triggered - during exit time - no Alarm / no report
Zone triggered - during entry time - no Alarm / no report
Installation Manual
AMAX panel 2000 / AMAX panel 2000 EN